Radon Basics
- Radon
- A naturally occurring radioactive gas (atomic number 86) produced by the decay of uranium in soil and rock. Radon is colorless, odorless, and tasteless — undetectable without a test. It enters buildings through foundation cracks, gaps around pipes, and other openings in contact with the ground.
- Radon Gas
- The gaseous form of radon (Rn-222) that seeps from soil into indoor air. Radon gas itself is chemically inert, but its radioactive decay produces solid particles — radon decay products — that lodge in lung tissue and emit alpha radiation.
- Picocuries per Liter (pCi/L)
- The standard unit for measuring radon concentration in air. One picocurie is one trillionth of a curie, representing about 2.2 radioactive disintegrations per minute. The EPA action level is 4.0 pCi/L; the average outdoor concentration is approximately 0.4 pCi/L.
- EPA Action Level (4.0 pCi/L)
- The radon concentration at or above which the U.S. EPA recommends mitigation: 4.0 picocuries per liter of air. The EPA also suggests homeowners consider mitigation for levels between 2.0 and 4.0 pCi/L, because no level of radon exposure is considered safe.
- Background Radiation
- The natural ionizing radiation present in the environment from cosmic rays, terrestrial sources, and naturally occurring radioactive materials such as uranium and thorium in soil. Average outdoor radon in the U.S. is about 0.4 pCi/L, a component of background radiation.
- Radon Decay Products
- The short-lived radioactive particles (polonium-218, lead-214, bismuth-214, polonium-214) produced when radon gas decays. Unlike radon gas, these solid particles attach to dust and aerosols, and when inhaled can lodge in lung tissue where their alpha radiation damages cells.
- Working Level (WL)
- A unit of measurement for the concentration of radon decay products in air. One working level equals any combination of short-lived radon decay products in one liter of air that results in the emission of 1.3 × 10⁵ MeV of alpha energy. The EPA action level of 4.0 pCi/L corresponds to approximately 0.016 WL under equilibrium conditions.
Source: U.S. EPARelated: Radon Gas, Radon Decay Products, Uranium Decay Chain
Source: U.S. EPARelated: Radon, Radon Decay Products
Source: U.S. EPARelated: EPA Action Level (4.0 pCi/L), Working Level (WL)
Source: U.S. EPARelated: Picocuries per Liter (pCi/L), Radon
Source: U.S. EPARelated: Radon, Uranium Decay Chain
Source: U.S. EPARelated: Radon, Working Level (WL), Lung Cancer (Radon-Related)
Source: U.S. EPARelated: Radon Decay Products, Picocuries per Liter (pCi/L)
Testing
- Short-Term Test
- A radon measurement lasting 2 to 90 days, typically 48–96 hours. Common devices include charcoal canisters and continuous radon monitors (CRMs). Short-term tests provide a snapshot of radon levels and are often used during real estate transactions.
- Long-Term Test
- A radon measurement lasting more than 90 days, typically using an alpha-track detector. Long-term tests better represent the year-round average radon level in a home and are the most accurate single measurement of annual exposure.
- Closed-House Conditions
- The test environment required for accurate radon measurements: all windows and external doors must remain closed except for normal entry and exit, beginning at least 12 hours before the test starts and continuing for the duration. Heating and air conditioning may operate normally, but whole-house fans that bring in outdoor air must be turned off.
- Continuous Radon Monitor (CRM)
- An electronic device that measures radon levels continuously — typically in hourly intervals — and reports the average concentration over the test period. CRMs detect tampering and record environmental conditions, making them the preferred device for real estate transactions.
- Charcoal Canister
- A passive radon testing device containing activated charcoal that adsorbs radon gas from the air over a 2–7 day exposure period. After exposure, the canister is sealed and sent to a laboratory for gamma spectroscopy analysis. Charcoal canisters are the most widely used short-term radon test.
- Alpha-Track Detector
- A passive radon measurement device containing a small piece of plastic film. Alpha particles from radon decay strike the film and leave microscopic tracks that are counted in a laboratory after the exposure period (typically 90 days to one year). The track density is proportional to the radon concentration.
- ANSI/AARST MALB
- The national standard for radon measurement in multifamily buildings: "Protocol for Conducting Measurements of Radon and Radon Decay Products in Multifamily Buildings." Published by the American Association of Radon Scientists and Technologists (AARST) and approved by the American National Standards Institute (ANSI). MALB governs testing protocol for apartment buildings, condominiums, and other multi-unit structures.
- ANSI/AARST MFLB
- The companion standard to MALB, covering radon mitigation in multifamily buildings: "Reducing Radon in Multifamily Buildings." Provides design and installation requirements for mitigation systems in multi-unit residential structures, including shared sub-slab systems and building-wide monitoring.
- DEP-Certified Tester
- A radon testing professional holding an active certification from the Pennsylvania Department of Environmental Protection under the Radon Certification Act (Act 43 of 1987). PA law requires anyone performing radon testing for compensation to hold this certification. Certification status is verifiable through the PA DEP Bureau of Radiation Protection.
- Post-Mitigation Test
- A radon test performed after a mitigation system is installed to confirm that radon levels have been reduced below the EPA action level of 4.0 pCi/L. ANSI/AARST standards require the test to begin no sooner than 24 hours after system activation, under closed-house conditions.
Source: U.S. EPARelated: Long-Term Test, Charcoal Canister, Continuous Radon Monitor (CRM), Closed-House Conditions
Source: U.S. EPARelated: Short-Term Test, Alpha-Track Detector
Source: ANSI/AARST MAHRelated: Short-Term Test, Long-Term Test
Source: ANSI/AARSTRelated: Short-Term Test, Closed-House Conditions
Source: U.S. EPARelated: Short-Term Test, Closed-House Conditions
Source: U.S. EPARelated: Long-Term Test
Source: ANSI/AARSTRelated: ANSI/AARST MFLB, Short-Term Test
Source: ANSI/AARSTRelated: ANSI/AARST MALB, Active Soil Depressurization (ASD)
Source: PA DEPRelated: DEP-Certified Mitigator, Act 43 (Radon Certification Act)
Source: ANSI/AARSTRelated: Short-Term Test, Closed-House Conditions, Active Soil Depressurization (ASD)
Mitigation
- Active Soil Depressurization (ASD)
- The most common and effective radon mitigation method. A contractor drills a suction point through the basement slab, inserts a PVC pipe, and connects it to a continuously running fan that creates negative pressure beneath the slab. This draws radon-laden soil gas out before it can enter the living space and exhausts it above the roofline.
- Sub-Slab Depressurization (SSD)
- A form of active soil depressurization where suction is applied beneath a concrete slab floor — the most common residential scenario. One or more suction points are drilled through the slab, and a fan draws soil gas from the aggregate layer beneath it and exhausts it outdoors.
- Sub-Membrane Depressurization (SMD)
- A form of active soil depressurization used in crawl spaces with dirt or gravel floors. A polyethylene membrane is sealed over the exposed soil, and a suction pipe and fan draw radon from beneath the membrane and exhaust it outdoors. Often combined with crawl space encapsulation.
- Passive Radon System
- A radon reduction system that relies on natural air pressure differentials and thermal stack effect — without a fan — to draw soil gas upward through a vent pipe and exhaust it above the roofline. Passive systems are typically installed during new construction and can be activated later by adding a fan if post-occupancy testing shows radon above the action level.
- Radon Vent Fan
- The continuously running in-line fan that powers an active soil depressurization system. Typically mounted in the attic or on the exterior of the building, the fan creates the negative pressure beneath the slab that prevents radon from entering the living space. Fan failure is the most common cause of system malfunction.
- Radon Vent Pipe
- The PVC piping (typically 3" or 4" Schedule 40) that carries soil gas from beneath the slab, through the building, and exhausts it above the roofline. The pipe must terminate at least 12 inches above the roof surface and 10 feet from any openable window or other opening into conditioned space, per ANSI/AARST standards.
- Sump Pit Cover
- An airtight lid sealed over a basement sump pit to prevent radon from entering the home through the pit opening. In many ASD installations, the sump pit serves as the suction point — the fan draws soil gas from beneath the slab via the pit rather than drilling a separate hole.
- Crawl Space Encapsulation
- The process of sealing a crawl space with a continuous vapor barrier (typically 6-mil or heavier polyethylene) over exposed soil and up foundation walls. When combined with sub-membrane depressurization, encapsulation blocks radon entry through the soil surface and improves the depressurization system's effectiveness.
- Heat Recovery Ventilator (HRV)
- A mechanical ventilation device that exchanges stale indoor air for fresh outdoor air while recovering heat energy from the exhaust stream. HRVs can reduce radon by diluting indoor air, but they are less effective than active soil depressurization and are typically used as a supplementary measure or where sub-slab systems are not feasible.
- RRNC (Radon-Resistant New Construction)
- Building techniques incorporated during new construction to prevent radon entry and facilitate future mitigation if needed. RRNC features include a gas-permeable aggregate layer beneath the slab, a polyethylene vapor barrier, sealed slab penetrations, and a vertical vent pipe from the sub-slab aggregate through the roof. Adding a fan later converts the passive system to active depressurization.
- PA DEP Standard 294-2309-002
- The Pennsylvania Department of Environmental Protection's technical guidance document governing radon mitigation standards and techniques for certified mitigators. Covers system design, installation requirements, post-mitigation testing, and documentation. All DEP-certified mitigators in Pennsylvania must follow this standard.
- DEP-Certified Mitigator
- A radon mitigation professional holding an active certification from the Pennsylvania Department of Environmental Protection under the Radon Certification Act (Act 43 of 1987). PA law requires anyone installing, repairing, or modifying radon mitigation systems for compensation to hold this certification, separate from the testing certification.
Source: U.S. EPARelated: Sub-Slab Depressurization (SSD), Radon Vent Fan, Radon Vent Pipe
Source: U.S. EPARelated: Active Soil Depressurization (ASD), Sump Pit Cover
Source: U.S. EPARelated: Active Soil Depressurization (ASD), Crawl Space Encapsulation
Source: U.S. EPARelated: Active Soil Depressurization (ASD), RRNC (Radon-Resistant New Construction), Radon Vent Pipe
Source: ANSI/AARSTRelated: Active Soil Depressurization (ASD), Radon Vent Pipe
Source: ANSI/AARSTRelated: Active Soil Depressurization (ASD), Radon Vent Fan
Source: ANSI/AARSTRelated: Sub-Slab Depressurization (SSD), Active Soil Depressurization (ASD)
Source: U.S. EPARelated: Sub-Membrane Depressurization (SMD)
Source: U.S. EPARelated: Active Soil Depressurization (ASD)
Source: U.S. EPARelated: Passive Radon System, Active Soil Depressurization (ASD)
Source: PA DEPRelated: DEP-Certified Mitigator, Active Soil Depressurization (ASD)
Legal & Disclosure
- PA Real Estate Seller Disclosure Law
- Pennsylvania's statutory framework (68 Pa.C.S. §§ 7301–7315) requiring residential property sellers to disclose known material defects to buyers. The mandatory disclosure form covers "presence of hazardous substances" at § 7304(b)(14), where any known elevated radon test result or existing mitigation system must be recorded.
- 68 Pa.C.S. § 7301
- The opening section of Pennsylvania's Real Estate Seller Disclosure Law, establishing the scope and definitions used throughout the statute. The law applies to the sale of residential real property and requires sellers to complete a property disclosure statement. Section 7308 clarifies that sellers have no affirmative duty to investigate conditions they are unaware of.
- Seller Disclosure Form
- The standardized property disclosure statement required by 68 Pa.C.S. § 7304 that residential sellers must complete and provide to buyers. The form requires disclosure of known hazardous substances (§ 7304(b)(14)), which includes any known radon test results and the presence of a mitigation system. Sellers who have never tested are not required to test.
- Radon Contingency
- A clause in a real estate purchase agreement that makes the sale conditional on the results of a radon test. If radon levels meet or exceed the EPA action level of 4.0 pCi/L, the buyer may request mitigation, negotiate a price reduction, or withdraw from the contract depending on the contingency terms.
- Radon Disclosure
- The legal obligation for residential property sellers in Pennsylvania to disclose known radon conditions to buyers under 68 Pa.C.S. § 7304(b)(14). Disclosure covers any known test results, the presence of a mitigation system, and whether the system is operational. The statute does not require testing — only disclosure of known results.
- Act 43 (Radon Certification Act)
- Pennsylvania's Radon Certification Act of 1987, which established the statewide requirement that all radon testing and mitigation professionals hold active certifications from the PA Department of Environmental Protection. Act 43 created the regulatory framework under which the DEP Bureau of Radiation Protection certifies testers and mitigators.
Source: 68 Pa.C.S. §§ 7301–7315Related: 68 Pa.C.S. § 7301, Radon Disclosure, Seller Disclosure Form
Source: 68 Pa.C.S. § 7301Related: PA Real Estate Seller Disclosure Law, Seller Disclosure Form
Source: 68 Pa.C.S. § 7304Related: PA Real Estate Seller Disclosure Law, Radon Disclosure
Source: PA Association of RealtorsRelated: PA Real Estate Seller Disclosure Law, Radon Disclosure, EPA Action Level (4.0 pCi/L)
Source: 68 Pa.C.S. § 7304Related: PA Real Estate Seller Disclosure Law, Seller Disclosure Form, Radon Contingency
Source: PA DEPRelated: DEP-Certified Tester, DEP-Certified Mitigator
Geology & Risk Factors
- Reading Prong
- A geological formation extending from eastern Pennsylvania through northern New Jersey into southeastern New York. The Reading Prong's Precambrian granitic gneiss and related metamorphic rocks are naturally high in uranium, producing some of the highest indoor radon levels in the United States. Counties overlying the Reading Prong — including Berks, Lehigh, and Northampton — consistently rank among Pennsylvania's highest for radon.
- Karst Limestone
- A terrain formed by the dissolution of soluble carbonate bedrock (limestone, dolomite, marble), characterized by sinkholes, caves, and underground drainage. Karst geology is prevalent across central Pennsylvania's Great Valley and promotes radon transport because fractured and dissolved rock provides pathways for soil gas to move rapidly toward building foundations.
- Marcellus Shale
- A Middle Devonian-age sedimentary formation underlying much of Pennsylvania, from the southwest corner through the northern tier. While primarily known for natural gas production, the Marcellus Shale contains naturally occurring radioactive materials (NORM) including uranium and radium. Counties overlying the Marcellus formation show variable radon levels depending on local fracturing, overlying soil, and glacial deposits.
- Uranium Decay Chain
- The sequence of radioactive decay steps starting from uranium-238 in soil and rock, passing through radium-226, and producing radon-222 gas. Each step in the chain emits radiation (alpha, beta, or gamma) as the nucleus sheds mass. Radon-222 is the only gaseous element in the chain, which is why it migrates from soil into buildings.
- Soil Permeability
- The ability of soil to transmit gas and water. Highly permeable soils (gravel, coarse sand, fractured rock) allow radon to travel farther from its point of origin and enter buildings more easily. Soil permeability, along with uranium content and foundation construction, is one of the three primary factors determining indoor radon levels.
- EPA Zone 1 (Highest Predicted Radon Potential)
- The highest EPA radon zone classification, assigned to counties with a predicted average indoor screening level at or above 4.0 pCi/L. In Pennsylvania, Zone 1 covers much of the south-central and southeastern regions, including counties in the Reading Prong and Appalachian ridge areas. Zone designations are county-level predictions — individual buildings may test higher or lower regardless of zone.
- EPA Zone 2 (Moderate Predicted Radon Potential)
- The moderate EPA radon zone classification, assigned to counties with a predicted average indoor screening level between 2.0 and 4.0 pCi/L. Zone 2 covers much of central and northeastern Pennsylvania. Elevated radon readings are common in Zone 2 counties, and the EPA recommends testing all homes regardless of zone classification.
- EPA Zone 3 (Lower Predicted Radon Potential)
- The lowest EPA radon zone classification, assigned to counties with a predicted average indoor screening level below 2.0 pCi/L. In Pennsylvania, Zone 3 includes parts of the Philadelphia metro area and a few southwestern counties. The EPA still recommends testing in Zone 3 because individual homes can have high radon regardless of the county average.
Source: USGSRelated: Uranium Decay Chain, EPA Zone 1 (Highest Predicted Radon Potential)
Source: USGSRelated: Soil Permeability, Uranium Decay Chain
Source: PA Geological Survey / USGSRelated: Uranium Decay Chain, Soil Permeability
Source: U.S. EPARelated: Radon, Radon Decay Products, Background Radiation
Source: USGSRelated: Uranium Decay Chain, Karst Limestone
Health
- Lung Cancer (Radon-Related)
- Lung cancer caused by inhaling radon decay products that lodge in lung tissue and emit alpha radiation, damaging cells over time. Radon is the second leading cause of lung cancer in the United States after smoking, responsible for an estimated 21,000 deaths per year according to the EPA. Risk increases with both concentration level and duration of exposure.
- WHO Radon Guidelines
- The World Health Organization's recommended reference level for radon in dwellings: 100 Bq/m³ (approximately 2.7 pCi/L), with a maximum of 300 Bq/m³ (approximately 8.1 pCi/L) where the lower level is not achievable. The WHO reference level is more stringent than the U.S. EPA action level of 4.0 pCi/L.
- Synergistic Risk (Radon + Smoking)
- The combined lung cancer risk from radon exposure and cigarette smoking, which is multiplicative rather than additive. A smoker exposed to elevated radon faces a substantially higher lung cancer risk than the sum of either risk alone. The EPA estimates that a smoker living with 4.0 pCi/L has approximately 5 times the lung cancer risk of a nonsmoker at the same radon level.
Source: U.S. EPARelated: Radon Decay Products, Synergistic Risk (Radon + Smoking)
Source: U.S. EPARelated: Lung Cancer (Radon-Related), Radon Decay Products
Related Resources